Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Braz. J. Pharm. Sci. (Online) ; 53(1): e15177, 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-839449

RESUMEN

Abstract In this study, conditions were optimized for development of a simple RP-HPLC method for simultaneous analysis of gatifloxacin and dexamethasone in different matrices like pharmaceuticals, human serum and urine. Good separation of gatifloxacin and dexamethasone from the induced degradation products was accomplished using C8 as stationary phase; 0.02 M phosphate buffer (pH 3.0) and methanol (42:58 v/v) as mobile phase. The concentration was measured with DAD at 270 nm. Linearity was observed in the range of 0.000040-0.000280 mol/L for gatifloxacin (r2≥0.999) and 0.000013-0.000091 mol/L for dexamethasone (r2≥0.999). Both the analyte peaks were completely separated from the peaks of induced degradation products as indicated by the peak purity index (≥0.9999 for both analytes). The optimized method is recommended to be used for concurrent analysis of gatifloxacin and dexamethasone in different matrices.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Estabilidad de Medicamentos , Cromatografía de Fase Inversa/métodos , Antibacterianos/análisis , Dexametasona/análisis , Estudio de Validación
2.
Braz. j. pharm. sci ; 49(2): 301-309, Apr.-June 2013. ilus, graf, tab
Artículo en Inglés | LILACS | ID: lil-680641

RESUMEN

The present study describes the development and subsequent validation of simple and accurate stability indicating RP-HPLC method for the determination of sparfloxacin and dexamethasone in pharmaceutical formulations in the presence of their stress-induced degradation products. Both the drugs and their stress-induced degradation products were separated within 10 minutes using C8 column and mixture of methanol and 0.02 M phosphate buffer pH 3.0 (60:40 v/v, respectively) as mobile phase at 270 nm using diode array detector. Regression analysis showed linearity in the range of 15-105 µg/mL for sparfloxacin and 5-35 µg/mL for dexamethasone. All the analytes were adequately resolved with acceptable tailing. Peak purity of the two drugs was also greater than 0.9999, showing no co-elution peaks. The developed method was applied for simultaneous determination of sparfloxacin and dexamethasone in pharmaceutical formulations for stability studies.


O presente estudo descreve o desenvolvimento e a subsequente validação de indicador de estabilidade simples e acurada por RP-HPLC para a determinação de esparfloxacino e dexametasona em formulações farmacêuticas na presença de produtos de degradação induzidos por estresse. Tanto os fármacos quanto os produtos de degradação induzidos pelo estresse foram separados em 10 minutos, utilizando coluna C8 e mistura de methanol e tampão fosfato 0,02 M, pH 3,0 (60:40 v/v, respectivamente) como fase móvel e detector de arranjo de diodo a 270 nm, A análise de regressão mostrou linearidade na faixa de 15-105 µg/mL para esparfloxacino e 5-35 µg/mL para a dexametsona. Todos os analitos foram resolvidos adequadamente com tailing aceitável. O pico de pureza dos dois foi maior que 0.9999, não mostrando picos de co-eluição. O método desenvolvido foi aplicado para a determinação simultânea de esparfloxacino e dexametasona em formulações farmacêuticas e para estudos de estabilidade.


Asunto(s)
Dexametasona/análisis , Química Farmacéutica/instrumentación , Cromatografía Líquida de Alta Presión/métodos , Preparaciones Farmacéuticas/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA